RP 330 Diagnostic Codes
LED Status Description
Green
Glows Tool ON.
Blinks Out of acceptable voltage range
— Cordless Tools: Replace battery with a fully charged battery.
— Corded Tools: Connect tool to a reliable voltage supply. If using extension cord,
use 16 AWG for 50' or less, 14 AWG for 50' to 100'.
Red
Blinks Jaws mounting pin not fully engaged. Insert pin.
Glows Out of temperature range -10°C (15°F) to 50°C (122°F).
Yellow
Blinks Service indicator after 30,000 cycles. NOTE: Tool will lock after 32,000 cycles.
Glows Machine is locked – Service after 32,000 cycles or after a malfunction.