Logs and Reports
Product name - Displays the product name.
Operator IDDisplays the entered identity of the test operator.
Test Samples FerrousDisplays the number of passes and the size of the Ferrous test
piece used.
Test Samples Non FerrousDisplays the number of passes and the size of the Non-
Ferrous test piece used.
Test Samples StainlessDisplays the number of passes and the size of the Stainless Steel
test piece used.
Detection ThresholdDisplays the working threshold limit for the product tested.
False Threshold Displays the false threshold used for the test.
PV Test PromptDisplays the status of the PV test prompt option, being either ON or OFF.
Batch Report
Purpose
The Batch Report contains a record of completed batch information. Batches can be compiled on a
time basis or on a count basis where the Production Registration PEC is fitted.
This log is useful for monitoring and analysing batch reject rates per product so that improvements
may be made to reduce production costs and also for monitoring product signals to review whether
the detector power may be adjusted to improve performance.
Running the Report
The report is automatically created and sent over the serial link to the connected device each time a
Batch is completed.
Batch completion may be automatically triggered by expiry of a time period or inspection of a
specified number of packs. This is set up in the Menus > Set Up > Batch Control menu.
Batch completion may also be manually triggered by resetting the batch data in the Menus > Results
menu.
Report Contents
The report contains information for the last 20 batches completed under the following column
headings:
DateDisplays the date that the report was generated.
TimeDisplays the time that the report was generated.
Machine IdentificationDisplays the machine ID value.
Product number - Displays the unique product number.
Product Identification - Displays the product name.
Batch start time - Displays the time that the batch started.
Batch finish time - Displays the time that the batch finished.
Number of packs passedDisplays the total number of packs inspected for the batch.
Number of good packs - Displays the number of packs in the batch that passed inspection.
Number of bad packs - Displays the number of packs in the batch that were rejected.
Maximum Signal - Displays the maximum product signal detected during the batch.
Average Signal All - Displays the average product signal across all packs inspected in the
batch.