SP-330, SP-330D, SP-500, SP-500A Submersible Sump Pumps
4
Specifications
Motor:
Type .....................................Shaded Pole
Rating ..................................120V, Single Phase
1/3 HP, 9.5 Amps
1/2 HP, 10 Amps
Pump
1/3 HP..................................3100 GPH @ 0 Ft.
1/2 HP..................................4400 GPH @ 0 Ft.
Liquid temperature range ....40F to 120F
Cut in level...........................9”
Cut out level.........................4”
Performance Curve
Performance Chart
Model Discharge Head 0’ 5’ 10’ 15’
SP-330 Gallons/Hour 3100 3000 2700 1680
SP-330D Gallons/Hour 3100 3000 2700 1680
SP-500 Gallons/Hour 4400 4100 3200 2000
SP-500A Gallons/Hour 4400 4100 3200 2000
Pump Installation
Pump should only be used to pump clear
water. Do not use to pump fluids such as gaso-
line, fuel oil, or kerosene. Do not use in a flam-
mable or explosive atmosphere. Improper use
could result in personal injury and/or death.
To prevent property damage,
serious injury, or death, proper installation of the
pump is required. The following procedures
should be followed:
!
WARNING
!
DANGER
Pump must be plugged into an outlet recepta-
cle that includes a Ground Fault Circuit
Interrupter (GFCI)
(Figure 1)
.
Always disconnect the power source before
attempting to install, service, relocate, or main-
tain the pump. Never handle a pump or pump
motor with wet hands or when standing on wet
or damp surface or in water.
Installation
1. Construct a sump pit from concrete, steel, or plas-
tic that is 24” deep and at least 11” in diameter
(Figure 2 next page)
. If the sump already exists,
make sure it is the proper size.
2. Make sure the electrical outlet is grounded and is
rated for 115 volts and at least 15 amps. The out-
let must be protected by a Ground Fault Circuit
Interrupter (GFCI).
Use of a grounded receptacle that
is protected by a GFCI reduces risk of a fatal electrical
shock.
3. Inspect the power cord and plug for damage. If the
plug is missing the grounding prong or the cord is
damaged, do not install the pump until the cord has
been replaced.
(Model SP-330D Diaphragm Switch only)
4. Remove the two fasteners in the cast iron volute
near the discharge area. Align the hole with the
diaphragm switch and replace the fasteners with-
out over tightening.
Figure 2 – Submersible Pump Installation
!
WARNING
25
20
15
10
5
1000 2000 3000 4000 5000 6000
Gallons Per Hour
Discharge (Feet)
SP-300
SP-300D
SP-500
SP-500A
0