PROBLEM PROBABLE FAULT LOCATION
The NaviTrack II locks up
during use.
NaviTrack II will not pick
up the signal.
While tracing, lines are
“jumping” all over the
screen in the mapping
display.
While locating a Sonde,
lines are “jumping” all
over the screen.
Distance between Sonde
and Poles is not equal.
Unit acts erratic, won’t
power down.
Display appears
completely dark, or
completely light when
it is turned ON.
There is no sound.
NaviTrack II will not turn
ON.
When using 93kHz
frequency the detector
does not receive
a signal.
Chart 1 Troubleshooting
Turn the unit OFF, and then back ON. Remove the batteries if the unit will not turn off. If batteries are
low, replace them.
Check that the correct mode and frequency is set. Examine circuit for possible improvements. Relocate
transmitter, change grounding, frequency, etc.
This indicates that the NaviTrack II is not picking up the signal or there is interference.
Make sure that the transmitter is well connected and grounded. Point the NaviTrack II at either lead to be
sure that there is a complete circuit.
Try a higher frequency, or connecting to a different point in the line, or switching to inductive mode.
Try to determine the source of any noise and eliminate it (Bonded, grounding, etc.).
Check the batteries in the Sonde to see that they are working.
Sonde may be too far away; try starting with it closer in if possible, or do an area search.
Verify signal by placing lower antenna close to Sonde. NOTE – Sondes have difficulty emitting signals
through cast iron and ductile iron lines.
Sonde may be tilted or there may be a cast iron to plastic transition.
Batteries may be low. Replace with fresh batteries and turn ON.
Power the unit OFF and then back ON.
Adjust the LCD screen contrast.
Adjust the sound level in the sound menu. Verify Proximity Signal is greater than zero.
Check orientation of batteries.
Check that the batteries are charged.
Check to see that the battery contacts are OK.
Unit may have blown a fuse (Factory service is required).
Try setting the receiver to the 93-B frequency as described on
page 17
.