TROUBLESHOOTING
PROBLEM CAUSE SUGGESTED CORRECTIVE ACTION
Brake does not stop blade
within 5 seconds.
1. Motor brushes not seated or
lightly sticking.
1. Inspect/clean/replace brushes. See
MAINTENANCE section.
2. Motor brake overheated from
use of defective or wrong size
blade or rapid On/Off cycling.
2. Use a recommended blade.
3. Arbor bolt is loose. 3. Retighten.
Motor does not start.
1. Fuse problem. 1. Check time delay fuse or circuit breaker.
2. Brush worn. 2. Replace brushes. See MAINTENANCE section.
Brush sparks excessively
when switch is released.
1. Brush worn/damaged. 1. Replace brushes. See MAINTENANCE section.
Blade hits table. 1. Misalignment. 1. See ADJUSTMENT section.
Angle of cut is inaccurate.
1. Miter table is unlocked.
1. Use miter-lock lever. See ADJUSTMENT
section.
2. Too much sawdust under table.
2. Vacuum or blow out dust. WEAR EYE
PROTECTION!
Cutting arm cannot fully
raise or blade guard
cannot fully close.
1. Parts failure. 1. Contact authorized service center.
2. Pivot spring not replaced
properly after service.
2. Contact authorized service center.
3. Sawdust buildup. 3. Clean and lubricate moving parts.
Blade binds, jams, or
burns wood.
1. Improper operation. 1. See OPERATION section.
2. Dull blade. 2. Replace or sharpen blade.
3. Improper blade. 3. Replace blade.
4. Warped blade. 4. Replace blade.
Saw vibrates or shakes. 1. Saw blade is damaged. 1. Replace blade.
2. Saw blade is loosened. 2. Tighten arbor bolt.
Laser line projection is
hard to see.
1. Light in work area is too bright.
1. Move the Miter Saw to the work area with
proper light.
2. Sawdust on the laser lens. 2. Clean laser lens with a soft, dry brush.